Ac Maintenance Service

Ac Maintenance Service

AC Maintenance Service Dubai:

What is the maintenance of air conditioning:

  • To extend service life
      • The lack of refrigerant gas and dirty heat exchangers greatly reduce the life of the compressor – the main element of the system
  • Air conditioning works at full capacity
      • In Middle East regions, like Dubai UAE, air conditioner heat exchangers are quickly polluted, which is why air conditioning blows with cold air.
      • The lack of refrigerant reduces the power of the system, because of what it will not cope with the cooling of the laid area of ​​the room
  • Reduce energy overruns
      • Air conditioning with a lack of refrigerant gas and dirty heat exchangers consumes more electricity than normal air conditioning
  • Damage Warnings
      • If you notice in time deviations in the operation of the equipment, you can save parts from failure 
      • For example expensive compressor when overheating
  • Smooth operation
      • Breakdowns occur at the most inopportune moment, it is better to eliminate them during preventive ac maintenance than in the heat, and wait for the arrival of the Ac Maintenance Companies

The durability of the air conditioner depends on :

  • conditions in which the air conditioner works
  • Installation quality
  • air conditioner manufacturer
  • Ac service

After-sales service minimizes the negative consequences of poor installation quality and poor environmental conditions.

How often do I need Ac Maintenance Service in Dubai?

This is influenced by the following factors:

  • clean air
  • how often do you use air conditioning
  • required degree of reliability ( cooling room or expensive equipment ) 

It all depends on how often the air conditioner is used and in what conditions.

But even if the air conditioner is clean in appearance and properly cools the room, this does not mean that everything is fine with it.

Only when diagnosing and measuring parameters, it is possible to determine deviations in its work and eliminate them prematurely, not allowing breakdowns.

What is included in the maintenance of air conditioning in Dubai?

Outdoor unit:

  • high pressure washing (Karcher)
  • check of working pressure and, if necessary, Refueling Refrigerant Gas
  • compressor current check
  • compressor insulation resistance check
  • wire pulling on the terminal block
  • detection and elimination of extraneous noise and vibrations
  • four-way valve check
  • checking the condition of the filters in the refrigerant circuit (if any)

Indoor unit:

  • heat exchanger (evaporator) cleaning
  • flushing the drainage system
  • fan cleaning
  • wire pulling on the terminal block

In the entire system:

  • freon/refrigerant gas leak detection
  • voltage measurement
  • tests on all operating modes
  • control panel check

Contact us

Ac Cleaning

Ac cleaning Dubai

Cleaning the air conditioner indoor unit:

  • Filter Wash
  • Evaporator treatment (internal heat exchanger)
  • Cleaning the fan impeller
  • Ac Drainage cleaning
      • drain pan
      • drain hose
      • drainage pump

Cleaning the external unit of the Air Conditioning system:

  • dry clean
  • high pressure water wash (karcher)
  • car wash

The cost affects:

  • Number of air conditioners (discount from 2 air conditioners)
  • Availability of air conditioning
  • (dismantling the ceiling, the release of the passage to the air conditioner)
  • Climber or aerial platform services
  • Night work

Ac Filter Wash

Dust coarse filters (grids, as many call them) are washed under running cool running water, drying is not required, moisture does not interfere with the operation of the air conditioner. The need for washing the filters can be determined by the presence of a layer of dust on them.

Ac Evaporator treatment

The evaporator is a coil of copper tubes with fins of thin aluminum plates – as in a car radiator, only the plates are thinner and more often located.

Evaporator processing types:

  • mechanical
  • chemical
  • antibacterial
  • high pressure washing

For mechanical Ac cleaning a special brush is used, which does not crush the ribs. It is used for heavy pollution.

Chemical treatment removes inorganic and organic contaminants from the evaporator – fats, soot layer, tobacco smoke particles, fine dust that accumulates passing through dust filters.

Sometimes, due to a layer of such dust, the air is completely not cooled when passing through the indoor unit. 

In case of contamination that cannot be removed by chemical means, the indoor unit is washed with a high-pressure washer – with a Karcher, with its dismantling and subsequent installation.

Antibacterial treatment of Ac will prevent the formation of fungi, mold and destroy the existing accumulations of bacteria in the air conditioner. Also, this measure will eliminate odors from the air conditioner.

For this purpose, special means are used, which are produced in aerosol cans, ready for use, or in the form of concentrates, which must first be diluted with water.

“Master of Cold” uses such tools for processing evaporators:

  • Easyclean
  • Easycare
  • Domestic means “Nanopirit”
  • Tophouse
  • Hydrocoil

All these tools have been tested and approved by manufacturers of air conditioners and condensate pumps.

Cleaning the fan impeller

With a small amount of contamination in Ac System, it can be cleaned with a brush, followed by chemical treatment.

If the contamination of the impeller is large, then it will have to be removed and washed.

Drainage cleaning

Gravity drain system

With this type of drainage, pollution often accumulates at bends or tapered areas. Effectively cleaned can be mechanically – purging with compressed gas. after that, it is necessary to spill the drain hose with water, preferably with the addition of chemical agents, as this will prevent the formation of mold and mildew, which also cause clogging of the drain hole and the hose.

Pump drainage system

Cleaning of this type of drainage system differs only in that it additionally has a float signal bath. It is necessary to monitor its purity most closely and regularly, since in the presence of dirt false alarms occur in it, which leads to the operation of the pump “dry” – this is the most common cause of the drain pump failure. The cost of replacing the pump is quite high, so we recommend regular cleaning of pump systems.

Ac indoor unit Cleaning

Dust filters (coarse filters) 

Dust filters are cleaned with cold running water, this procedure is available to any air conditioner user.

The frequency of washing the filters – in fact, on the frequency of use and the degree of air pollution. Learn what you need to clean the filter by opening the air conditioner panel – if the filters has accumulated a layer of dust, they should be washed under running water, if the contamination is not removed, it is recommended to use neutral cleaners.

Ac outdoor unit Cleaning

How necessary is this procedure?

Many people think that after the removal of dry brush “carpet” of poplar fluff and dust outdoor unit is completely pure and it is possible to finish the cleaning.

In fact, as it does not sound paradoxical, this “carpet” often does not interfere with the normal condensation of freon, only slightly delaying the passage of air through the edges of the condenser.

Particularly worsen the heat exchange particles of exhaust gases, grease and dust deposited on the inner surface of the ribs. Experts are well aware that when washing with high pressure water a clean-looking condenser, which even “shines through”, very dirty water flows out of it and, moreover, for a long time.

If your air conditioner is in the area of ​​exhaust emissions, increased dust formation and other air pollutants, it should be regularly washed with a high-pressure washer.

How to wash the Air conditioner in Dubai?

A condenser is needed for washing – a heat exchanger consisting of copper tubes with aluminum fins.

In order not to bend the edges of the water stream is required to direct strictly parallel to the ribs. To do this, direct the stream to the rear (or front) of the condenser and wash the entire surface evenly.

If the location allows, then this can be done with a simple straight nozzle, available in any wash set. But in most cases, this requires a corner nozzle, allowing to penetrate into the space between the wall and the outdoor unit.

Disassembling the case or washing the air conditioners on the fan side is not correct, it does not make sense. 

Contact us

 

Preparing Air Conditioner for hot weather in dubai

Work on the prevention of split Ac systems:

  • Cleaning the indoor unit: filters, housing, heat exchanger, fan
  • Cleaning the outdoor unit
  • Check leak detector refrigerant gas
  • Checking the pressure in the system and refilling the refrigerant (refrigerant gas)
  • Rolling compound pulling
  • Clearing the drainage system: drain pan, drain hose, pump
  • Wire pulling in terminal block
  • Checking the operating current of the compressor
  • Noise elimination
  • Check the control panel
  • Checking the air conditioner in all modes of operation

How often should prophylaxis be carried out?

It depends on such factors:

  • how often is air conditioning used
  • how clean is the air outside
  • whether quality air conditioning is installed
  • uptime criticality

It is clear that if the air conditioner is used around the clock and constantly, then it becomes dirty much faster than its counterpart, which is included only when necessary.

The more dust and dirt on the street and in the room, the more often it is necessary to wash the filters of the indoor unit (this is quite up to the owner of the air conditioner) and clean the heat exchangers of the indoor and outdoor units. This is especially noticeable in the season of “poplar fluff” – the outdoor unit can be covered with a dense “fur coat” in just a few days.

The better the consumables and tools, and the more professional the installation of the air conditioner, the less refrigerant gas will be leaked and the less ac gas refueling will be needed.

If the air conditioner does not work for several days in the apartment or in the office, it’s unpleasant, but not critical, but if the air conditioner of the server’s cooling system breaks down, expensive equipment may fail, a break in the work of the whole department, loss of important data. It will already be quite critical and it is necessary to monitor the condition of air conditioners regularly in order to prevent split-system failure in time. 

Preparing for the winter season – conservation

Domestic split systems do not require mandatory preservation for the winter.

Contact us

HVAC Circuit Board Repair

HVAC Circuit Board Repair for air conditioners

All Done Ac Maintenance Co. LLC specialists repair control boards of any brand of air conditioners from Daikin and Mitsubishi, to Chinese air conditioners of unknown brands, repair air conditioner PCB boards in Dubai.

Boards are repaired regardless of the design – wall Ac, duct Ac, cassette Ac, sub ceiling Ac, column types Air Conditioners.

PCB Repair at the customer’s Location

After receiving the inquiry/complaint, the Ac service team arrives at the call, diagnoses the malfunction and repairs the control board immediately on the spot.

Each Ac Maintenance Van has the necessary supply of basic radio elements and, in case it is possible, repairs the board on the spot.

The cost of the work will include: departure service crew and diagnostics, repair of the air conditioner board itself, removal and installation of the board with disassembly and assembly of the air conditioner.

Repair in the Ac service center

If on-site it was not possible to repair the PCB board, the repair team removes it and delivers it to the service center where the radio-electronics specialists restore its working capacity.

Specialists of the Ac service center in Dubai will identify the malfunction and repair the Ac PCB board in case of failure of the microchips, relays, and other radio components. In case there are no original parts, they will select a fully functional analog of reliable manufacturers.

It is also possible to  independently  bring a fee to our service center.

To do this, you must send an email to our email in which will be:

  • Photo of the nameplate of the air conditioner itself, where the model is clearly visible
  • A photograph of the board and places of damage in good quality
  • Scan (photo) of the diagnostic act
  • Describe the symptoms of faults and air conditioning errors (if any)

The term of repair of control boards (PCB) of air conditioners depends on the availability of parts and can vary from 30 minutes to a week, each case is negotiated with the client individually.

Remote transformer

Sometimes the transformer is located not on the board itself, but next to it, in the case of the air conditioner, in which case it must also be brought, since the cause of the malfunction may lie in it.

If the air conditioner has a control board (PCB) in an external unit, then the air conditioner needs to be diagnosed on site, since from experience about 50% of the diagnostic results are false and the board is not faulty, but other elements – sensors, valves, compressor.

ATTENTION!

If you are not an expert and do not understand what is going on, then you must call and consult. Get ready to provide photos and tell the story of the breakdown.

Contact us

Why is the Air Conditioner noisy?

Is your Air Conditioner noisy?

Noisy Ac Maintenance Company Dubai

Noise from the indoor unit

Usually, the noise from the air conditioner appears several years after using the Ac without service, or even during its operation.

But there are also possible extraneous sounds immediately after the installation of the split system.

It is very important to correctly identify the source of the noise, after that, knowing the cause, it will be much easier to eliminate unpleasant sounds.

Causes of Ac noise:

Fan noise

    • fan bearing

      • during operation, a roar is heard, the fan stops immediately after shutdown, scrolls with a small

    • grazing

      • Usually in old air conditioners due to warping and deformation of plastics

    • grazing ice

      • details of the reasons for the formation and elimination of ice are described in the article

Buzz off

  • buzz is not loud, but prevents to fall asleep

  • common in cheap Chinese air conditioners

  • problem is solved by replacing the power transformer

Hiss on power

  • the cause is the flow of refrigerant in the air conditioner tubes

  • manifests when the tubes break and the section narrows

  • also observed when clogged internal cavities tubes

  • after installation of used air conditioners

Air Conditioner vibration

  • sometimes the air conditioner can vibrate very much, almost flying off the mounts on the wall

  • the reason is the imbalance of the fan impeller

  • can fly off a balancing weight (like on car disks)

  • more often the cause is severe contamination of the impeller – unbalancing occurs either because of the irregularity of the pollution along the length or after a piece of dirt flies off from a small area

Noise drainage pump

  • drainage pump starts to crack when it fails, in this case you need to clean or replace the pump

  • crackling will also occur when the air conditioner is idle for a long time, as the pump produces a crackling sound when it is dry, it will stop after a short cod

Noise from the Ac outdoor unit

Since the external units of air conditioners are installed in close proximity to the internal one, most often outside the window, therefore, the noise from the external unit sometimes gets in the way, especially at night, not only to the owner of the air conditioner, but also to his neighbors.

Causes of noise from the external unit

No vibration damping rubber gaskets

  • vibration dampers located between the brackets and legs of the air conditioner
  • they reduce the transmission of vibrations from the air conditioner to the wall

The mounting bracket bolts are in contact with the metal reinforcement of the reinforced concrete wall

  • at the same time there is a feeling that the wall is vibrating

  • it is possible to eliminate only by drilling holes in another place (near) and moving the fixings

Compressor wear

  • after many years of operation and lack of maintenance, the compressor will have extraneous noises and vibrations

Fan noise

  • grazing and foreign objects are often caught

  • ice grazing in heating mode

  • overtones from design elements

  • cheap air conditioners often vibrate lattice elements, covers

  • usually solved by removing them or by laying seals

  • do not be afraid to remove non-functional elements, they serve only for appearance and they are often saved

We have analyzed the main causes and ways of dealing with noisy air conditioners, but it is worth remembering that after many years of work, the equipment will not work as new, especially if the main body material is plastic.

Contact us

Difference Between Inverter Air Conditioner and Classic Ac

Inverter Ac Maintenance Dubai 

This article is written to answer questions from air conditioners’ users, so that a simple person can understand the difference between inverter air conditioners and ordinary ones.

This is written on many resources, but most of them are a set of certain stamps and are aimed at persuading a person to purchase a more expensive inverter air conditioner , regardless of the buyer’s needs.

Sometimes there are articles in which nonsense is written, compiled by a marketer rather than a technical specialist.

The authors are not particularly puzzled by the proof of the information given, they simply rewrite articles from each other.

The difference between inverter and “on / off” air conditioners

Structurally:

  • In the inverter there is an electronic power board in the external unit, in the classic there is no
  • Compressor motors have different operating principles.

Everything else – the type of electric motors of fans, the type of TRV, and other technical nuances depend on the model of the air conditioner , and not on the method of power control.

By the method of power control:

  • Inverter – continuously adjustable power
  • On / off-air conditioning – speed, cyclic

Advantages of inverter air conditioners: myths and reality

So, according to the sales organizations, the inverter air conditioner:

  • Saves electricity
  • It works more quietly
  • Less harmful to health
  • More durable
  • More reliable than non-inverter

Below we analyze each item separately, what is true and what does not correspond to reality or is a clever marketing move.

Energy saving air conditioning in Dubai

Manufacturers of air conditioners promise energy savings when using an inverter up to 30%.

Unfortunately, all the studies are conducted by the manufacturers of refrigeration equipment themselves.

A very popular visual comparison scheme is the process of cooling and driving, which is not correct and does not reflect the essence of the process.

At the same time, an electronic unit appears in the inverter air conditioner, which is not found in a conventional air conditioner.

In the inverter module, some of the electricity is lost, which is converted into heat.

The volume of losses is clearly visible in the size of the radiator, which is installed to remove heat in the outdoor unit.

In any case, even with a maximum savings of 30%, taking into account the cost of electricity, and the difference in the cost of inverter and classic air conditioners, the payback period is more than three years.

When using the air conditioner only in summer in cooling mode, for a short period of time, the payback period increases.

For European countries, the period is shortened due to higher tariffs for electricity, so inverter air conditioners are more popular there.

If the air conditioner breaks, the payback period may move for an indefinite period due to the high cost of the inverter ac spare parts.

Inverter air conditioners have low noise

Split system consists of two blocks – internal and external, we consider them separately.

Indoor unit:

It is located indoors and its noise level does not depend on the way the compressor is controlled (as it is located in the outdoor unit outside).

The noise produced by the air conditioner depends on the flow rate of the exhaust air and the aerodynamic qualities of the fan impeller and the casing.

That is, the noise level of the indoor unit depends on the specific model of the air conditioner, but not on the inverter control of the compressor.

To reduce the noise level, manufacturers use a special profile of the fan impeller and the shape of the outlet.

It often happens that cheap Asian inverters are noisier compared to branded non-inverter models of air conditioners.

External unit:

In modern air conditioners are installed so quiet compressors that the main noise creates a fan.

Fan operation is also independent of compressor control technology.

An air conditioner that is malfunctioning or improperly mounted can vibrate and make noise, for example, when a fixing bolt has fallen into a reinforcement in a concrete wall and directly transmits sound and vibrations to it.

Read more about the causes of air conditioning noise here .

Air Conditioners life

As the manufacturers and trading organizations promise, the average service life of an inverter air conditioner is about two times longer than an inverter air conditioner and is 8-15 years (different companies have different information).

The service life of the air conditioner is increased by increasing the service life of the compressor, since the number of starts in the inverter air conditioner is reduced and there are no high starting currents, which reduces compressor wear.

And now let’s remember the old Soviet refrigerators – for many they worked for twenty years, and the compressors felt quite normal.

You can still remember the air conditioners BC – Baku window-sill, they can now be seen in working condition.

And imported air conditioners of the O-general, Super General, Daikin,, Toshiba or Sanyo brands, imported at the beginning of the restructuring, are discarded during repairs only because of their unsightly appearance. But they worked according to the classical scheme, without an inverter converter.

So the conclusion suggests itself, air conditioner compressors are very reliable and durable devices, of course, if they are made at a factory of a well-established company.

But the compressor may fail due to poor installation:

  • When moisture enters the cold compartment, an acid is formed that destroys the insulation of the engine
  • In case of oil leakage, the compressor will operate without lubrication.

Or in the absence of service:

  • The compressor will operate under reduced pressure if it is not refueled in time.
  • The compressor can operate at elevated pressure and load if the heat exchangers are not cleaned in time.

It does not matter whether the inverter air conditioner or normal, the compressor will break in that and in another case.

Another factor affecting the service life of an air conditioner is that the inverter ac has additional electronic cards – a power board that provides power conversion and compressor power, and a control card that provides communication with the indoor unit and control of the power unit.

The boards may break due to overvoltage or due to overheating of the power module, the protection does not always cope with its function.

Often, electronics is a weaker link than a compressor.

Inverter air conditioners accurately maintain the room temperature

Due to the change in compressor performance, the inverter air conditioner is able to quite accurately maintain the set air temperature.

But there is one “but.” The process of cooling the air in the room has a certain inertia, that is, it takes some time to cool it.

Now imagine any office, the air conditioner is working, the door has opened – a client has come, a kettle has been turned on, a computer has been turned off, someone has opened a window.

Naturally, temperature stability is out of the question.

Of course, another thing is a bedroom or children’s room, in these rooms the inverter can quite accurately maintain the temperature.

Disadvantages of inverter air conditioners

  • High price
  • Break more often
  • Expensive parts and long delivery time

Inverters electronic filling is completely different, and from time to time fails.

The cost of the boards is from 10 000 p., Which is comparable to the cost of some non-inverter air conditioners, plus the cost of replacing the board. Repairing the board is not always possible due to the fact that manufacturers use power modules that are not commercially available.

It is because of the inverter electronics that are less reliable than conventional air conditioners, this is especially true for Russia, where the quality of the mains supply is very unstable.

But technologies do not stand still and maybe soon the inverter will completely replace the old type air conditioners.

In addition, all new technologists who appear are used primarily in inverter models – economical compressors with DC motors, twin-rotor compressors, with extremely low vibration levels, swing rotor compressors, with reduced friction force, fan blades with a special low-noise profile and etc.

Which air conditioner to choose, inverter or classic?

An inverter air conditioner is more suitable for a bedroom, as its another advantage is in partial power mode, temperature maintenance, the air temperature at the exit from the indoor unit is higher than from the usual one, which reduces the risk of a cold from the air conditioner.
The choice of the type of air conditioner depends on the goals, that is, what room it will cool.

But in the premises with a short-term stay of people or with uneven and abrupt heat leakage all the advantages of the inverter are lost.

Since inverters are technically more complex products, the price for them is obviously higher.

With a limited budget, the best choice would be to purchase a non-inverter air conditioner of middle or higher class than an inverter split-system of low level.

Since the technical characteristics of such air conditioners are better, and the reliability is even more so.

Therefore, the choice is yours, but you must not forget that the more expensive the air conditioner, the more expensive its repair.

Application area Recommended air conditioning Note
Bedroom Inverter Less risk of catching cold
Kitchen Non inverter All the advantages of inverters become invisible.
Office Non inverter The design look is not important;

The noise of any air conditioner is blocked by the office noise;

The acquisition of an inverter will not have time to pay off, for example, it will break or the office will change the place of rent.

The shops Non inverter No matter the appearance and noise characteristics
Server Non inverter In an emergency it is easier to repair and quickly find analog parts.

Contact us

Bryant Air Conditioners Error Codes

Bryant Air Conditioners Error Codes

Bryant Ac Maintenance Dubai

Table 19 shows the status codes flashed by the amber status light.Most system problems can be diagnosed by reading the status code as flashed by the amber status light on the control board.

The codes are flashed by a series of short and long flashes of the status light. The short flashes indicate the first digit in the status code, followed by long flashes indicating the second digit of the error code.

Bryant Air Conditioners Error Codes

A NOTE ABOUT SAFETY Any time you see this symbol in manuals, instructions and on the unit, be aware of the potential for personal injury. There are three levels of precaution: DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards that could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.

PERSONAL INJURY, DEATH AND / OR PROPERTY DAMAGE HAZARD Failure to follow this warning could result in personal injury, death or property damage. Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or service agency must use factory–authorized kits or accessories when modifying this product. Read and follow all instructions and warnings, including labels shipped with or attached to unit before operating your new air conditioner.

ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury or death. Disconnect all electrical power to the indoor air handler or furnace before removing access panels to perform any maintenance. Disconnect power to both the indoor and outdoor units.

Bryant Air Conditioners Heat Pumps Troubleshooting Dubai

Fault: System Communications Failure

Possible Cause And Action: Communication with User Interface lost. Check wiring to User Interface, indoor and outdoor units

Fault: Invalid Model Plug

Possible Cause And Action: Control does not detect a model plug or detects an invalid model plug. Unit will not operate without correct model plug

Fault: High Pressure Switch Open

Possible Cause And Action: High —pressure switch trip. Check refrigerant charge, outdoor fan operation and coils for airflow restrictions

Fault: Low Pressure Switch or Discharge Temp Switch Open

Possible Cause And Action: Low -pressure switch or discharge temperature switch trip. Check refrigerant charge and indoor air flow.

Fault: Control Fault

Possible Cause And Action: Outdoor unit control board has failed. Control board needs to be replaced.

Fault: Outdoor Air Temp Sensor Fault

Possible Cause And Action: Outdoor air sensor not reading or out of range. Ohm out sensor and check wiring

Fault: Outdoor Coil Sensor Fault

Possible Cause And Action: Coil sensor not reading or out of range. Ohm out sensor and check wiring

Fault: Thermistors out of range

Possible Cause And Action: Improper relationship between coil sensor and outdoor air sensor. Ohm out sensors and check wiring

Fault: Low Stage Thermal Cutout

Possible Cause And Action: Compressor operation detected then disappears while low stage demand exists. Possible causes are internal compressor overload trip or start relay and capacitor held in circuit too long

Fault: High Stage Thermal Cutout

Possible Cause And Action: Compressor operation detected then disappears while high stage demand exists. Possible causes are internal compressor overload trip or start relay and capacitor held in circuit too long

Fault: Low Stage Thermal Lockout

Possible Cause And Action: Thermal cutout occurs in three consecutive low/high stage cycles. Low stage locked out for 4 hours or until 24v power recycled.

Contact us

Beko AC Error Codes and Troubleshooting

Beko Ac Error Codes and Trouble Shooting

Beko Ac Maintenance Dubai

When air conditioner status is abnormal, temperature indicator on indoor unit will blink to display corresponding error code. Please refer to blow list for identification of error.

Error Codes Cause
H1 Means defrosting status. It’s the normal phenomenon.
E5 It can be eliminated after restarting the unit. If not, please contact qualified professionals for service.
U8 It can be eliminated after restarting the unit. If not, please contact qualified professionals for service.
H6 It can be eliminated after restarting the unit. If not, please contact qualified professionals for service.
C5 Please contact qualified professionals for service.
F1 Please contact qualified professionals for service.
F2 Please contact qualified professionals for service.

Note: If there’re other error codes, please contact qualified professionals for service.

Warning

When below phenomenon occurs, please turn off air conditioner and disconnect power immediately, and then contact the dealer or qualified professionals for service.

  • Power cord is overheating or damaged.
  • There’s abnormal sound during operation.
  • Circuit break trips off frequently.
  • Air conditioner gives off burning smeel.
  • Indoor unite is leaking.

*Do not repair or refit the air conditioner by yourself.
*If the air conditioner operates under abnormal conditions, it may cause malfunction, electric shock or fire hazard.

Beko AC Troubleshooting

Check the following points before requesting repairs or service. If the fault persists, please contact your dealer or service center.

*The air conditioner does no operate.
-Have you made a mistake in timer operation?
-Has the fuse blown or has the circuit breaker been tripped?

*The room has a peculiar odor.
-Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room.

*It seems that condensation is leaking from the air conditioner.
-Condensation occurs when the airflow from the air conditioner cools the warm room air.

*Air conditioner does not operate for about 3 minutes when restarted.
-This is the protector of the mechanism.
-Wait about three minutes and operation will begin.

*Does not cool or heat effectively.
– Is the air filter dirty? See air filter cleaning instructions.
– Has the temperature been set incorrectly?
– Are the indoor unit’s air inlet or outlet vents obstructed?

*The air conditioner operation is noisy.
-For a noise that sounds like water flowing. This is the sound of freon flowing inside the air conditioner unit.
-For a noise that sounds like the compressed air releasing into atmosphere. This is the sound of the dehumidifying water being processed inside the air conditioning unit.

*Remote control display is faint, or no display at all.
-Are the batteries depleted?
-Are the batteries inserted in the opposite (+) and (-) directions?

*Crack sound is heard.
This sound is generated by the expansion/constriction of the front panel, etc. due to changes of temperature.

Contact us

Aux AC Error Codes and Troubleshooting

Aux Ac Error Codes and Trouble Shooting

Aux Ac Maintenance Dubai

AUX Air Conditioning Error Codes;

1.HS(Y) HSA(Y) HSB(Y) HSF (Y) HV(Y) HVA(Y) digital display for the series air-conditioner faults:

Error Codes Problem
E4 PG motor feedback is abnormal. The display precedence level: 1
E1 Plastic temp sensor is abnormal. The display precedence level: 2
E3 Copper temp sensor is abnormal (indoor). The display precedence level: 3
E2 Copper temp sensor is abnormal (outdoor). The display precedence level: 4

2. H (Except KFR-25G/H) H1 HA HB series faults display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3
  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

3. H(Y) Model air conditioner fault display:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3
  • Fault source: Copper temp sensor is abnormal (outdoor)
  • Display mode: Timing light twinkles 1 times in every 1 seconds
  • The display precedence level: 4

4. EA EC EM EY EZ EAA EAD EL HS1 HSZ HL1 HLZ P P1 ZZ CZ digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: E3
  • The display precedence level: 3

5. All of the other E series except EA EC EM EY EZ EAA EAD:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal (indoor)
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3

6. QA QB QD digital display series ac faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E4
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E1
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3
  • Fault source: Over-current oprotection
  • Display mode: E6
  • The display precedence level: 4

7. QC QQ light display series air-conditioner faults:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 4 times in every 8 seconds
  • The display precedence level: 1
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 3 times in every 8 seconds
  • The display precedence level: 3
  • Fault source: Over-current oprotection
  • Display mode: Timing light twinkles 6 times in every 8 seconds
  • The display precedence level: 4

8. Faults display of 18000BTU~24000BTU wall unit series ac non-digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: Timing light twinkles 1 times in every 8 seconds
  • The display precedence level: 2
  • appearance: System turns off
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: Timing light twinkles 2 times in every 8 seconds
  • The display precedence level: 3
  • appearance: System turns off
  • Fault source: Copper temp sensor is abnormal
  • Display mode: Timing light twinkles 8 times in every 8 seconds
  • The display precedence level: 4
  • appearance: System doesn’t turns off

Digital tube displays:

  • Fault source: PG motor feedback is abnormal
  • Display mode: E1
  • The display precedence level: 2
  • appearance: System turns off
  • Fault source: Plastic temp sensor is abnormal
  • Display mode: E3
  • The display precedence level: 3
  • appearance: System turns off
  • Fault source: Copper temp sensor is abnormal
  • Display mode: E2
  • The display precedence level: 4
  • appearance: System doesn’t turn off
  • E1: Temperature sensor of air intake fault
  • E2: Temperature sensor of outdoor coil fault
  • E3: Temperature sensor of indoor coil fault
  • E4: PG motor of indoor unit feedback fault

AUX Air Conditioning Wall Mounted Error Codes

Self-check information: Hint to defrosting

  • Self-check code of luminotron: Flicker 1 time/1s
  • Digital self-check code: Indicates “dF“or defrosting indicator displays

Self-check information: Hint to defense against cold wind

  • Self-check code of luminotron: Flicker 1 time/3s
  • Digital self-check code: Fan motor picture not running

Self-check information: Failure of room temperature sensor

  • Self-check code of luminotron: Flicker 2 times/4s (Flicker 2 times/8s)
  • Digital self-check code: E2/(L2)

Self-check information: Failure of coiled pipe sensor

  • Self-check code of luminotron: Flicker 3 times/5s (Flicker 1 time/8s)
  • Digital self-check code: E3/(L1)

Self-check information: Abnormality of outdoor unit

  • Self-check code of luminotron: Flicker 4 times/6s (luminating)
  • Digital self-check code: E4/(E5)

Self-check information: Without feedback of internal fan motor

  • Self-check code of luminotron: Flicker 5 times/7s (Flicker 6 times/8s)
  • Digital self-check code: E5/(L6)

Self-check information: Zero crossing signal without current

  • Self-check code of luminotron: Flicker 6 times/8s
  • Digital self-check code: E6

Self-check information: External feedback failure

  • Self-check code of luminotron: Flicker 7 times/9s
  • Digital self-check code: E7

Self-check information: Overheat protection

  • Self-check code of luminotron: Flicker 8 times/10s
  • Digital self-check code: E8

Self-check information: Water pump failure

  • Self-check code of luminotron: Flicker 9 times/11s
  • Digital self-check code: E9

Troubleshooting Guide

Problem: The motor is heard operating but the air-conditioner dose not work when the indoor unit is powered on

Cause: Since the air-conditioner is powered on, it will come to working condition as long as you press the ON/OFF button of the remote control and the signal is well received.

Problem: The compressor stops running but the indoor fan motor keeps working when it is at cooling mode with the indoor temperature higher than set temperature.

Cause: If you turn off the air-conditioner and restart it immediately, it will return to normal in 3 minutes, after that, the air-conditioner will automatically adjust the indoor fan speed to what you set.

Problem: The compressor works discontinuously at dehumidifying mode.

Cause: The air-conditioner will automatically control the working of the compressor according to the inside temperature

Problem: The air-conditioner dose not work while the LED display is on.

Cause: The TIMER is set with the air-conditioner,it will be in hold on condition. If the TIMER setting is cancelled, the air-conditioner will return to normal working condition.

Problem: The compressor works discontinuously at cooling and dehumidifying mode, and the indoor fan motor slows down.

Cause: The compressor stops internally or the fan motor slows down to prevent the indoor heat exchanger from being frozen.

Contact us

Amvent Air Conditioner Error Codes

Amvent Air Conditioner Error Codes

Amvent Ac Maintenance Dubai

Amvent Mini Split AC; In case of error, the display on the indoor unit shown the following error codes:

E1-flashes once -The fault of indoor temperature senser

E2-flashes twice-The fault of indoor pipe temperature senser

E6-flashes 6 times-Malfunction of indoor fan motor

Troubleshooting

Malfunction: The Air Conditioner does not operate

Possible Causes:

  • Ac Power failure/plug pulled out
  • Ac Damaged indoor/outdoor unit Ac fan motor
  • Faulty compressor thermomagnetic circuit breaker
  • Faulty protective device or fuses.
  • Loose connections or plug pulled out
  • It sometimes stops operating to protect the appliance.
  • Voltage higher or lower than the voltage range
  • Active TIMER-ON function
  • Damaged electronic control board (PCB)

Malfunction: Strange odour

Possible Causes: Dirty Ac air filter

Malfunction: Noise of running water

Possible Causes: Back flow of liquid in the refrigerant circulation

Malfunction: A fine mist comes from the air outlet

Possible Causes: This occurs when the air in the room becomes very cold, for example in the COOLING or DEHUMIDIFYING/DRY modes

Malfunction: A strange noise can be heard

Possible Causes: This noise is made by the expansion or contraction of the front panel due to variations in temperature and does not indicate a problem.

Malfunction: Insufficient airflow, either hot or cold

Possible Causes:

  • Unsuitable temperature setting.
  • Obstructed air conditioner intakes and outlets.
  • Dirty air filter.
  • Fan speed set at minimum.
  • Other sources of heat in the room.
  • No refrigerant.

Malfunction: The appliance does not respond to commands

Possible Causes:

  • Remote control is not near enough to indoor unit.
  • The batteries of remote control nearly has no power.
  • Obstacles between remote control and signal receiver in indoor unit.

Malfunction: The display is off

Possible Causes:

  • Active LIGHT function
  • Power failure

Malfunction: Switch off the air condi- tioner immediately and cut off the power supply in the event of

Possible Causes:

  • Strange noises during operation.
  • Faulty electronic control board
  • Faulty fuses or switches.
  • Spraying water or objects inside the appliance.
  • Overheated cables or plugs.
  • Very strong smells coming from the appliance.

Contact us